Our Mission Statement
NOJA Power provide high quality, quality assured medium voltage recloser related products and services to an international market. Use the links below to explore our available products.
News 2011
2011 March NOJA Power Commissioned to Supply Switchboard For Airport Link Project
News 2010
2010 December NOJA POWER Expands its Type Testing Capabilities
2010 November NOJA POWER Environmental Management System ISO14001 Certified
2010 July NOJA Power elevated to National Master Electrician Status
2010 June NOJA Power OSM38 KEMA Type Testing Completed
2010 March NOJA Power Motor Control Centres Empowers Queensland Coal Export
2010 March NOJA Power Auto Recloser Perfect Solution for Sectionalising
2010 March NOJA Power Low Voltage Motor Control Centres, Specify for Safety, Reliability and Performance
2010 June NOJA POWER OSM38 KEMA Type Testing Completed
2010 Febuary TELUS and OSM Recloser Provide Smart Grid Solution
2010 January NOJA Power Auto Recloser Operating Smart Grids Below Freezing
News 2009
2009 October NOJA Power Winner of the 2009 Premier of Queensland's Exporter of the Year Award
2009 August Trade Queensland International Business Cadetship Successfully Completed
2009 August Kanban & Lean Manufacturing Improve Productivity
2009 August NOJA Power OSM27 Type Tested at KEMA
2009 August NOJA Power New Corporate Office and Factory
2009 Feburary NOJA Power Reclosers to Increase Distribution Network Reliability in Brazil
2009 Feburary Powerco Successfully Commissions Automatic Backfeed Restoration Scheme
2009 Feburary NOJA Power Continues to Supply MCCs for Abbot Point Coal Export Upgrade
News 2008
2008 November ENERGEX Awards NOJA Power a Recloser Supply Contract as Part of Network Upgrade Program
2008 September Factory Expansion Increases Production Capabilities
2008 August Practical Perspective on Recloser Training
2008 August NOJA Powers Brisbane Clem Jones Tunnel
2008 June NOJA Power Commended on Manufacturing Endeavours
2008 June OSM Reclosers helps Mine through Bat Season
2008 May NOJA Power exhibits OSM Recloser reliability at IEEE Conference
2008 April NOJA Power Awarded for Exporting Success
2008 April Brazilian Intern Graduates & Joins NOJA Power Distributor
2008 March NOJA Power Teams up to Supply PNG Power
2008 March Solid-Dielectric ACR Installation Improves Distribution Network Reliability
2008 Feburary NOJA Power to Exhibit at Upcoming IEEE PES Conference & Exhibition
News 2007
2007 October NOJA Power Switchgear Pty Ltd Appoints Exclusive Distributor for the Territory of New Zealand
2007 September Fiji Electricity Authority Contract Award
2007 September ENERGEX Reaps Benefits of OSM Installations
2007 August Planning for the future: Water Matters
2007 August ETSA Utilities Award 5 Year Supply Contract
2007 August NOJA Power & Comulsa exhibit at Exponor Conference, Chile
2007 January Gold Coast Airport upgrades using OSM Recloser
News 2006
2006 November NOJA Power receives AEEMA Excellence in Exporting Award 2006
2006 November Trinidad & Tobago Electricity take delivery of NOJA Power OSM Reclosers
2006 September NOJA Power welcomes new member to sales team
2006 August Fiji Electricity Authority Remote Controls NOJA Power Reclosers
2006 July New Shipment to Bangladesh
2006 June A Global Bank to Support A Global Business
2006 June Motor control centres come as standard
2006 June Standard design for motor control centres improves quality
2006 August Fiji Electricity Authority Remote Controls NOJA Power Reclosers
2006 May Think Motor Control Centres - Think NOJA Power
2006 May 132kV Substation Protection and SCADA control project
2006 May Reliable power thanks To NOJA Power reclosers
2006 May Live line work: Is your switchgear fault contained?
OSM Recloser helps Mine through Bat Season
Every dry season in the northern topics of Australia bats roost in large numbers. During the night they take to the skies in search of food and fly into power lines causing frequent outages. This can cause havoc with 24-hour mining operations which have to clear the lines and replace expensive fuses on almost a nightly basis..
GBS Gold's processing plant is situated in Pine Creek, 250km south of Darwin in the Northern Territory of Australia. Outages caused by bats on the 11kV overhead distribution system costs thousands of dollars with the amount of fuses are used each dry season. Costs associated with lost productivity of staff who are required to manually change these fuses adds to the annual expense caused by this problem - all at a time when gold has been at record prices.
![]() OSM Recloser installation to reduce maintenance costs and lost production time at GBS Mine |
Maintenance staff at the mine made numerous efforts to minimize the effects of bat strikes on the lines, but nothing seemed to have a lasting impact. After asking around other mines in the region for any solutions to the bat problem, the electrical supervisor at GBS Gold, Paul Barnes, was told about the NOJA Power recloser installation at the Sally Malay Nickel mine for this exact purpose.
GBS Gold had two main objectives - minimize disruption to the processing plan and stop replacing expensive fuses. Two OSM15 reclosers were purchased so that the distribution line could be sectionalized into two separate segments. A fuse saving strategy was employed in the protection settings so the reclosers would isolate the faulted line without blowing the fuses.
NOJA Power configured each recloser to operate three shots to lockout, allowing the power to be restored if the bat falls free from the line during the dead time of each operation. In the event that the bat remains on the line, the recloser will go to lockout after three trips and sectionalise the faulted section of feeder, leaving the rest of the processing plant still operational.
The return on investment for these reclosers is expected to be almost instant. When the cost of replacing the fuses, lost production and maintenance time is taken into consideration, the cost of installing the two OSM reclosers will show a positive return to the operation before the first bat season has finished.
The OSM recloser is well suited to this type of application. Numerous faults occur during the bat season and the 30,000 operation rating of the OSM means it will easily last the distance. The NOJA Power OSM recloser is also the lightest and smallest on the market today, ensuring ease of installation on distribution lines where weight and space is important.
Following the successful installation of the first recloser, NOJA Power Service Engineer, Brian O’Sullivan, conducted basic operation training with the electrical and maintenance crew that was cut short with the appearance of a 3.5 metre crocodile on site.
The maintenance team was also impressed with the well thought out package supplied in the crate. NOJA Power pre-assembled the surge arrestors and connecting bars on the bushings, supplied molded bushing boots to fit the arrangement and supplied insulated water-blocked cable pre-stripped at the ends for convenience. The installation team was able to place the crate at the base of the pole and install the OSM recloser with ease.

