Our Mission Statement
NOJA Power provide high quality, quality assured medium voltage recloser related products and services to an international market. Use the links below to explore our available products.
News 2011
2011 March NOJA Power Commissioned to Supply Switchboard For Airport Link Project
News 2010
2010 December NOJA POWER Expands its Type Testing Capabilities
2010 November NOJA POWER Environmental Management System ISO14001 Certified
2010 July NOJA Power elevated to National Master Electrician Status
2010 June NOJA Power OSM38 KEMA Type Testing Completed
2010 March NOJA Power Motor Control Centres Empowers Queensland Coal Export
2010 March NOJA Power Auto Recloser Perfect Solution for Sectionalising
2010 March NOJA Power Low Voltage Motor Control Centres, Specify for Safety, Reliability and Performance
2010 June NOJA POWER OSM38 KEMA Type Testing Completed
2010 Febuary TELUS and OSM Recloser Provide Smart Grid Solution
2010 January NOJA Power Auto Recloser Operating Smart Grids Below Freezing
News 2009
2009 October NOJA Power Winner of the 2009 Premier of Queensland's Exporter of the Year Award
2009 August Trade Queensland International Business Cadetship Successfully Completed
2009 August Kanban & Lean Manufacturing Improve Productivity
2009 August NOJA Power OSM27 Type Tested at KEMA
2009 August NOJA Power New Corporate Office and Factory
2009 Feburary NOJA Power Reclosers to Increase Distribution Network Reliability in Brazil
2009 Feburary Powerco Successfully Commissions Automatic Backfeed Restoration Scheme
2009 Feburary NOJA Power Continues to Supply MCCs for Abbot Point Coal Export Upgrade
News 2008
2008 November ENERGEX Awards NOJA Power a Recloser Supply Contract as Part of Network Upgrade Program
2008 September Factory Expansion Increases Production Capabilities
2008 August Practical Perspective on Recloser Training
2008 August NOJA Powers Brisbane Clem Jones Tunnel
2008 June NOJA Power Commended on Manufacturing Endeavours
2008 June OSM Reclosers helps Mine through Bat Season
2008 May NOJA Power exhibits OSM Recloser reliability at IEEE Conference
2008 April NOJA Power Awarded for Exporting Success
2008 April Brazilian Intern Graduates & Joins NOJA Power Distributor
2008 March NOJA Power Teams up to Supply PNG Power
2008 March Solid-Dielectric ACR Installation Improves Distribution Network Reliability
2008 Feburary NOJA Power to Exhibit at Upcoming IEEE PES Conference & Exhibition
News 2007
2007 October NOJA Power Switchgear Pty Ltd Appoints Exclusive Distributor for the Territory of New Zealand
2007 September Fiji Electricity Authority Contract Award
2007 September ENERGEX Reaps Benefits of OSM Installations
2007 August Planning for the future: Water Matters
2007 August ETSA Utilities Award 5 Year Supply Contract
2007 August NOJA Power & Comulsa exhibit at Exponor Conference, Chile
2007 January Gold Coast Airport upgrades using OSM Recloser
News 2006
2006 November NOJA Power receives AEEMA Excellence in Exporting Award 2006
2006 November Trinidad & Tobago Electricity take delivery of NOJA Power OSM Reclosers
2006 September NOJA Power welcomes new member to sales team
2006 August Fiji Electricity Authority Remote Controls NOJA Power Reclosers
2006 July New Shipment to Bangladesh
2006 June A Global Bank to Support A Global Business
2006 June Motor control centres come as standard
2006 June Standard design for motor control centres improves quality
2006 August Fiji Electricity Authority Remote Controls NOJA Power Reclosers
2006 May Think Motor Control Centres - Think NOJA Power
2006 May 132kV Substation Protection and SCADA control project
2006 May Reliable power thanks To NOJA Power reclosers
2006 May Live line work: Is your switchgear fault contained?
Live Line Work - Is Your Switchgear Arc Fault Contained?
Using live-line techniques to install medium voltage reclosers is increasingly popular amongst electrical utilities and is done to minimize disruption to customers. Although common practice, what are the safety issues, and how can switchgear manufacturers design products which increase safety for live-line workers?
NOJA Power's Managing Director, Mr Neil O'Sullivan, says the answer is to use arc fault contained and vented reclosers that comply with the requirements of IEC60298 Annex AA.
“Not all reclosers on the market today are arc-fault contained and this should concern those responsible for the safety of live-line workers”, he said.
“NOJA Power has the only arc-vented, solid dielectric, SF6 free, product on the market today. In situations where SF6 gas is not desirable, and installation is to be live-line, our reclosers are the only safe choice”, he said.
Pole mounted switchgear have evolved dramatically over the years. Early switchgear used oil, while later designs used oil or SF6 gas for insulation combined with vacuum interruption. It has since been discovered that SF6 is a greenhouse gas and the by-products created when using SF6 gas for interrupting arcs are carcinogenic.
The challenge for pole mounted switchgear manufacturers has been to find safe, viable, long life alternatives to using oil and SF6 gas in their products.
This has seen the introduction of vacuum interrupted solid dielectric products into the market. The majority of these use vacuum interrupters embedded inside cyclo-aliphatic epoxy resin poles. Magnetic actuator mechanisms are used on each pole to operate the device. The actuators are normally encased in a mild steel or stainless steel housing which provides the base plate for mounting the poles.
This type of switchgear design is available from several manufacturers. Although it achieves the goal of eliminating harmful insulants such as SF6 and oil, is this really a safer, longer life product?
These products do not provide arc fault containment and venting as required by IEC60298 Annex AA.
It can be argued that it is not possible to achieve a phase to phase arc fault with three separate poles. However, it is still possible to achieve a phase to ground fault and this can propagate.

Pressure Relief Valve
If this occurs, arc fault containment is essential for the safety of anyone in the immediate vicinity. Unfortunately, the design described above lacks this essential feature.
Electrical utilities must consider the risks of installing switchgear live-line which are not arc-fault contained and vented. A combined insulation system with arc fault containment is the safe answer to this issue.
The dielectric strength of a combined insulation system is higher than the insulating material itself. This effect is generated by the barrier hindering the chain reaction of molecule ionisation required for electrical breakdown across air.
The combined insulation system must provide the mechanical strength to withstand the forces associated with arc fault containment and fault level interruption. It must also be IP66 water proof and shaped to ensure electrical fields are minimised to withstand the required BIL/flashover levels.
Various insulation materials with different properties are used within NOJA Power's design. Silicone for joins and flexible areas, polymers for rigid structures that provide strength. High pressure processes are used for each material to eliminate voids that can cause partial discharge problems.
NOJA Power's patented arc fault containment and venting is achieved by manufacturing the tank from 304 grade stainless steel and providing an arc vent in the pole side of the tank.Reclosers will continue to play a critical role in the future of overhead line protection. Designs which offer a longer life and solid dielectric insulation systems with arc fault containment and venting should be specified by all electricity utilities when considering future recloser purchase specifications.